loading

High Power Liquid Cooling Cold Plate

KingKa's High Power Liquid Cooling Cold Plate is engineered for electronics that have outgrown air cooling. High-purity copper or stainless-steel tubes are embedded into a CNC-machined aluminum base using our proprietary Hi-Contact process, moving heat away from dense, high-flux components far more efficiently than fin-and-fan solutions.

Every plate is built to your thermal budget rather than a catalogue guess. Our engineering team runs CFD simulation against your component map, then tunes channel layout, pass count and tube spacing so the plate holds your target junction temperature under real operating load.
Availability:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button

Construction and Materials

Each high-power plate starts from a CNC-machined Aluminum 6061/6063 base into which high-purity Copper 1100 or Stainless Steel SUS 304 tubes are set using KingKa's proprietary Hi-Contact pressing. Thermal epoxy is then applied at every tube-to-plate joint to eliminate air gaps, producing a dense, gap-free thermal path that draws heat from the component face straight into the coolant.

Key Characteristics

Embedded tube architecture

Hi-Contact pressing maximizes tube-to-plate contact area and minimizes interface thermal resistance for fast, even heat pickup.

Copper or SUS tube options

Choose Copper 1100 for maximum conductivity or SUS 304 for corrosion resistance against aggressive coolants and harsh environments.

Tight-tolerance CNC channels

3-, 4- and 5-axis machining holds channel geometry to +/-0.005 mm for a precise tube fit.

Gap-free thermal interface

Thermal epoxy at every joint eliminates microscopic air gaps that would otherwise insulate the interface.

Validated zero-leak assembly

100% airtightness leak detection and two-stage flow testing confirm every plate before shipment.

Technical Specifications

Base Plate Material Aluminum Alloy 6061 / 6063 (1100/5052/7075 on request)
Cooling Tube High-purity Copper 1100 or Stainless Steel SUS 304
Integration Technology Proprietary Hi-Contact pressing + thermal epoxy (gap-free interface)
CNC Machining Tolerance +/-0.005 mm (milling); +/-0.005 mm (turning)
Surface Flatness Fly-cut & ground; verified by Kett testers
Leak Testing 100% airtightness detection (4 LCP testers)
Flow Validation Two-stage flow-resistance test
Dimensional Inspection Hexagon CMM +/-0.001 mm; 2.5D projector
Internal Cleanliness Airtight cleaning, residue-free channels
Quality System ISO 9001:2015; IATF 16949:2016

Note: the table lists KingKa's verified build options and, where applicable, the standard part number and dimensions. Final geometry, passes, ports and finish are confirmed against your drawing.

Manufacturing and Quality Control

KingKa controls every step of the build in-house, from incoming-material inspection to final flow testing. The workflow below reflects the construction used for this High Power Liquid Cooling Cold Plate.

Process flow

  • Material sourcing & IQC. Base plates use Aluminum 6061/6063 (1100/5052/7075 on request); cooling tubes use High-purity Copper 1100 or Stainless Steel SUS 304. All incoming metal is inspected by SQE and IQC teams.

  • CNC channel routing & tube bending. 3-, 4- and 5-axis CNC centers mill the channel layout to +/-0.005 mm and bend the tubes to match your component footprint.

  • Hi-Contact pressing & thermal epoxy. Tubes are forcefully embedded by KingKa's proprietary Hi-Contact technique, then thermal epoxy fills every joint to remove air gaps and lock the assembly.

  • Leak & flow validation. Every plate passes 100% airtightness leak detection (4 dedicated LCP testers) and a two-stage flow-resistance test.

What we verify on every plate

  • 100% airtightness leak detection — four dedicated LCP leakage testers confirm every assembly.

  • Two-stage flow-resistance test — channels are clear and pressure-stable.

  • Hexagon CMM & 2.5D projector — dimensional verification to +/-0.001 mm against your drawing.

  • Airtight internal cleaning — residue-free channels, safe for diverse coolants.

  • Salt-spray & Kett film/roughness — corrosion and surface-finish validation per batch.

Application Scenarios

This High Power Liquid Cooling Cold Plate is specified for thermal management where air cooling is no longer sufficient or where space, weight or noise are constrained:

  • IGBT and high-power modules (GTO, SiC, GaN)

  • High-performance computing and GPU accelerators

  • Industrial power supplies and converters

  • EV powertrain power electronics

Customization and OEM Service

KingKa designs each plate from your STEP/CAD file and thermal budget rather than a catalogue shape. Channel layout, pass count and tube spacing are simulated in CFD against your component map, then prototyped and verified before volume release.

Procurement Advantages

For buyers, KingKa is a direct manufacturer with 16+ years of thermal-production experience, 50+ CNC centers (3-/4-/5-axis) and 60,000+ parts per year, certified to ISO 9001:2015 and IATF 16949:2016. Engineering support includes in-house CFD thermal simulation and 3D design before tooling.

  • From drawing to volume. Send your STEP/CAD file and thermal budget for a CFD-backed proposal.

  • Flexible supply. Standard items ship from stock in 1-2 days; custom samples typically 7-15 days.

  • One quality system. Prototype, pilot and production all carry 100% leak and CMM inspection.

  • R&D backing. Dongguan Nancheng R&D center supports design, validation and scale-up.


Previous: 
Next: 
Get a Quote Now

PRODUCTS

QUICK LINKS

CONTACT US

   Tel: +86 13712444018 
   E-mail: sales2@kingkatech.com 
    Add: Da Long Add: New Village,Xie Gang Town, Dongguan City, Guangdong Province, China 523598
Leave a Message
Get a Quote Now
Kingka Tech Industrial Limited    All rights reserved     Technical Support: Molan Network