Liquid Cooling Cold Plate

KingKa's Liquid Cooling Cold Plate is a versatile thermal building block for high-power electronics. Embedding conductive tubes in a CNC-machined aluminum base lets you replace bulky air-cooled heatsinks with a compact, quiet and far more capable liquid path.

Available with copper or stainless-steel tubes and fully customizable in layout, pass count and footprint, the plate scales from a single power module to a rack of compute or conversion hardware.
Availability:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button

1

Construction and Materials

This general-purpose plate embeds conductive Copper 1100 or SUS 304 tubes in a CNC-machined Aluminum 6061/6063 base using Hi-Contact pressing and thermal epoxy, giving a compact liquid path that replaces bulky air-cooled heatsinks.

Key Characteristics

Material flexibility

Copper 1100 for conductivity or SUS 304 for corrosion resistance, in the same aluminum-base platform.

Hi-Contact embedded tubes

Proprietary pressing maximizes contact area and minimizes interface resistance.

Precision CNC channels

+/-0.005 mm channel routing for a perfect tube fit.

Gap-free epoxy interface

Thermal epoxy eliminates insulating air gaps at every joint.

Validated zero-leak build

100% leak and flow testing on every plate.

Technical Specifications

Base Plate Material Aluminum Alloy 6061 / 6063 (1100/5052/7075 on request)
Cooling Tube High-purity Copper 1100 or Stainless Steel SUS 304
Integration Technology Proprietary Hi-Contact pressing + thermal epoxy (gap-free interface)
CNC Machining Tolerance +/-0.005 mm (milling); +/-0.005 mm (turning)
Surface Flatness Fly-cut & ground; verified by Kett testers
Leak Testing 100% airtightness detection (4 LCP testers)
Flow Validation Two-stage flow-resistance test
Dimensional Inspection Hexagon CMM +/-0.001 mm; 2.5D projector
Internal Cleanliness Airtight cleaning, residue-free channels
Quality System ISO 9001:2015; IATF 16949:2016

Note: the table lists KingKa's verified build options and, where applicable, the standard part number and dimensions. Final geometry, passes, ports and finish are confirmed against your drawing.

Manufacturing and Quality Control

KingKa controls every step of the build in-house, from incoming-material inspection to final flow testing. The workflow below reflects the construction used for this Liquid Cooling Cold Plate.

Process flow

  • Material sourcing & IQC. Base plates use Aluminum 6061/6063 (1100/5052/7075 on request); cooling tubes use High-purity Copper 1100 or Stainless Steel SUS 304. All incoming metal is inspected by SQE and IQC teams.

  • CNC channel routing & tube bending. 3-, 4- and 5-axis CNC centers mill the channel layout to +/-0.005 mm and bend the tubes to match your component footprint.

  • Hi-Contact pressing & thermal epoxy. Tubes are forcefully embedded by KingKa's proprietary Hi-Contact technique, then thermal epoxy fills every joint to remove air gaps and lock the assembly.

  • Leak & flow validation. Every plate passes 100% airtightness leak detection (4 dedicated LCP testers) and a two-stage flow-resistance test.

What we verify on every plate

  • 100% airtightness leak detection — four dedicated LCP leakage testers confirm every assembly.

  • Two-stage flow-resistance test — channels are clear and pressure-stable.

  • Hexagon CMM & 2.5D projector — dimensional verification to +/-0.001 mm against your drawing.

  • Airtight internal cleaning — residue-free channels, safe for diverse coolants.

  • Salt-spray & Kett film/roughness — corrosion and surface-finish validation per batch.

Application Scenarios

This Liquid Cooling Cold Plate is specified for thermal management where air cooling is no longer sufficient or where space, weight or noise are constrained:

  • Power electronics and IGBT modules

  • Servers, GPUs and high-performance computing

  • Automotive and EV systems

  • Industrial conversion and control equipment

Customization and OEM Service

Available as standard or fully custom. Send your thermal load, footprint and coolant type; KingKa returns a CFD-backed layout and lead-time quote.

Procurement Advantages

For buyers, KingKa is a direct manufacturer with 16+ years of thermal-production experience, 50+ CNC centers (3-/4-/5-axis) and 60,000+ parts per year, certified to ISO 9001:2015 and IATF 16949:2016. Engineering support includes in-house CFD thermal simulation and 3D design before tooling.

  • From drawing to volume. Send your STEP/CAD file and thermal budget for a CFD-backed proposal.

  • Flexible supply. Standard items ship from stock in 1-2 days; custom samples typically 7-15 days.

  • One quality system. Prototype, pilot and production all carry 100% leak and CMM inspection.

  • R&D backing. Dongguan Nancheng R&D center supports design, validation and scale-up.


Previous: 
Next: 
Get a Quote Now

PRODUCTS

QUICK LINKS

CONTACT US

   Tel: +86 13712444018 
   E-mail: sales2@kingkatech.com 
    Add: Da Long Add: New Village,Xie Gang Town, Dongguan City, Guangdong Province, China 523598
Leave a Message
Get a Quote Now
Kingka Tech Industrial Limited    All rights reserved     Technical Support: Molan Network